SECTION 7: PROPANE CONNECTION
Figure 39
— Page 33 —
NOTE: The 375 LP and Manual Shut-off Valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psi (3.5 kPa).
Manual Shut-Off Valve for
Propane Supply Installed in
Propane Inlet Port
NOTE: The 375 LP must be isolated from the gas supply
piping system by closing its individual manual shut
-off valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than 1/2 psi (3.5 kPa).