SECTION 10: PURGING THE SYSTEMS
— Page 44 —
NOTE: The propane burner may not light on the first
attempt if air is still present in the line. It will at-
tempt to light automatically three times, and once
propane is present, it will light successfully. The
first light may be noisy, but the second light
should be purged and stable.
Purging the Propane System
1. Ensure that the propane line from the RV pro-
pane tank to the Aqua-Hot has propane avail-
able.
2. Attach the propane inlet line from the RV pro-
pane tank to the Aqua-Hot’s “Propane Inlet
Only!” port.
3. Open the manual shut-off valve (ball valve) at
the Aqua-Hot’s propane inlet port and allow
propane to fill the Aqua-Hot’s internal line fully.
At this point ensure that the connections to the
unit are not leaking propane gas.
4. Remove the propane line from the propane
burner’s gas valve to bleed any air in the line un-
til propane is present. Reference Figure 53.
Internal Propane
Connection to the
Propane Burner’s Gas
Valve
(to be disconnected during initial
Propane hookup and purging)
Figure 53
5. Reattach the propane line to the propane
burner’s gas valve and tighten completely to
avoid leaks.
6. Ensure that the interior room thermostats are set
to their highest position in order to call for heat,
then turn the burner switch on the interior
switch panel to “on.”
7. Once the burner is lit successfully, the system
is purged.